Installation & Setup Guide for Cleantouch Cold Storage ControllerThis guide walks you step-by-step through preparing for installation, mounting the Cleantouch Cold Storage Controller, making electrical and sensor connections, performing initial configuration, and verifying proper operation. It includes safety notes, tips for common issues, and recommended maintenance to keep your cold storage system reliable and compliant with food-safety standards.
Safety and preparation
- Read the Cleantouch product manual and local electrical codes before beginning.
- Turn off power to the refrigeration circuit at the breaker before wiring.
- Use a qualified electrician for mains connections if you are not certified.
- Wear appropriate PPE: insulated gloves, safety glasses, and non-slip footwear.
- Ensure the installation area is dry and protected from direct spray or excessive condensation.
- Verify the controller model and firmware are compatible with your refrigeration system and sensors.
Tools and materials needed
- Phillips and flat-head screwdrivers
- Wire strippers and crimpers
- Multimeter (voltage, continuity, resistance)
- Drill and mounting hardware (anchors, screws)
- Heat-shrink tubing or insulated terminals
- Cable ties and conduit for cable management
- Temperature sensors (provided with the controller or compatible models)
- Ethernet cable or Wi‑Fi access details (if controller supports network features)
- Laptop or mobile device for configuration (if required)
Unboxing and inspection
- Open the packaging and confirm the presence of:
- Cleantouch Cold Storage Controller unit
- Temperature/humidity sensors and extension cables (if included)
- Mounting template or bracket
- Power connector or wiring harness
- Quick-start guide and safety documentation
- Inspect all components for physical damage. Do not install damaged parts.
- Record the controller serial number and firmware version for reference.
Site selection and mounting
- Choose a location inside the cold room where the controller is accessible, dry, and within reach of sensors and power. Avoid areas with direct airflow from evaporator fans or doors.
- Maintain clearance for ventilation around the controller as specified in the manual.
- Use the provided mounting template to mark screw locations. Drill holes and install anchors if mounting to concrete or masonry.
- Secure the controller housing to the wall using appropriate screws. Ensure the unit is level and firmly attached.
Wiring overview
Note: Wiring diagrams may vary by model. Refer to the specific Cleantouch wiring diagram included with your unit.
- Main power input (AC): Connect live (L), neutral (N), and protective earth (PE) to the designated terminals. Confirm voltage rating matches your supply.
- Relay outputs: These control compressor, defrost, alarm, fans, and other devices. Common labels: COMP, DEF, FAN, ALARM. Use rated contactors/relays for high-current loads.
- Sensor inputs: Connect temperature and optional humidity sensors to the sensor terminals. Observe polarity where applicable. Keep sensor cabling separate from high-voltage wiring to reduce interference.
- Alarm contacts: Connect dry contacts or siren/strobe circuits as required.
- Communication ports: If present, connect Ethernet, RS-485, or USB according to your network plan.
Sensor placement and cabling
- Place primary temperature sensor in a location that represents average conditions—for example, mid-room at product level or near the return air path. Avoid placing directly in the airstream from the evaporator or next to doorways.
- For multi-sensor setups, position sensors at loading/unloading areas, near evaporators, and at product pallets for spot checks.
- Route cables through conduit where possible, securing with cable ties and keeping them away from motors and power lines.
- Use the recommended cable type and maximum run length per the manual. If the run exceeds recommendations, use shielded cable or place repeaters as advised.
Electrical connections and commissioning
- With the power still OFF, complete all wiring and tighten terminal screws to the recommended torque.
- Double-check wiring against the wiring diagram and confirm no stray strands could short.
- Turn ON power and verify the controller boots correctly. Observe the startup sequence on the display or LEDs.
- Use a multimeter to verify relay outputs energize as expected when manually commanded from the controller interface.
- Check sensor readings on the controller match independent thermometer readings within the device’s specified tolerance.
Initial configuration
- Set basic parameters:
- Date and time (important for logs and alarms).
- Temperature setpoints: cooling setpoint, high/low alarms, and differential/hysteresis.
- Defrost schedule: time-based or sensor/accumulator triggered, duration, and defrost termination method.
- Fan control behavior and staging if multiple fans are used.
- Alarm thresholds and actions (local alarm, remote notification, phone/email if networked).
- Configure relays and outputs mapping to match your equipment (compressor contactor, defrost heater, fan motor starter, alarm output).
- If the controller supports networking, enter Wi‑Fi or Ethernet settings, IP address (static or DHCP), and server/cloud integration credentials if used.
- Save configuration and, if possible, export or back up the settings to a USB or cloud account.
Functional tests
- Cooling cycle test:
- Set the temperature setpoint lower than the current room temperature to force a cooling call. Verify compressor relay and contactor engage and evaporator fan operation.
- Defrost cycle test:
- Initiate a manual defrost and verify defrost relay energizes, fans shut off if configured, and defrost termination occurs per settings.
- Alarm test:
- Simulate an alarm (e.g., set a high-temperature condition) and verify audible/visual alarms and any remote notifications.
- Sensor failure test:
- Disconnect a sensor to confirm the controller reports sensor fault and triggers configured fail-safe actions.
- Power-fail recovery:
- Simulate power loss and restoration to verify the controller resumes correct operation and log entries are recorded.
Logging, reporting, and calibration
- Verify data logging is active and storing temperature, alarms, and event history. Set logging interval (e.g., 1–5 minutes) per storage capacity and regulatory needs.
- Configure automatic report generation if supported (daily/weekly temperature logs for HACCP compliance).
- Calibrate sensors if necessary using a certified reference thermometer. Apply offsets in the controller settings when adjustments are needed. Record calibration data and dates.
Common installation issues and troubleshooting
- Controller not powering on:
- Check mains breaker, fuses, and terminal connections. Verify incoming voltage with a multimeter.
- Inaccurate temperature readings:
- Confirm sensor placement, wiring continuity, and proper calibration. Replace sensor if out of tolerance.
- Relays not actuating:
- Verify output configuration, measure coil voltage on outputs, and ensure external contactors are functional.
- Network connectivity problems:
- Verify IP settings, network credentials, firewall rules, and physical connection quality. Try a direct connection for debugging.
- Frequent defrosting or short cycling:
- Check door seals, excessive product load, fan operation, and sensor placement. Adjust hysteresis and setpoints if needed.
Maintenance and best practices
- Inspect wiring and terminal tightness every 6–12 months.
- Clean the controller enclosure and vents; keep free of dust and condensation.
- Verify sensor calibration annually or per regulatory requirements.
- Keep firmware up to date — follow Cleantouch release notes and update procedure. Back up configuration before updating.
- Maintain event logs and calibration records for HACCP and audit purposes.
Final checklist before handover
- Controller mounted and powered.
- All wiring completed, labeled, and secured.
- Sensors placed and verified.
- Setpoints, alarms, and schedules configured.
- Functional tests (cooling, defrost, alarm, failover) passed.
- Documentation, wiring diagrams, calibration records, and user manual provided to the operator.
- Operator trained on basic operation, alarm response, and manual overrides.
If you want, I can adapt this into a printable checklist, provide step-by-step images for wiring, or produce a short operator training sheet.